Fire pressure switch
Category:
Pressure switch
- Product Description
-
According to the standard 1.0.4 of GB50974-2014, "Technical Specifications for Fire Water Supply and Fire Hydrant Systems", a flow switch or pressure switch should be installed on the outlet pipe of the high-level fire water tank to directly start the fire pump. According to the new standard GB509742014.11.0.19, the reliability of the system's pump start-up was previously often affected by the loss of weak electrical signals. Therefore, the necessity of starting the fire pump via the fire hydrant box button is low, and the investment in fire hydrant button pump starting is relatively large. Therefore, the fire hydrant button should not be used as a direct pump starting signal, but only as an alarm signal. A flow switch is installed on the outlet pipe of the high-level water tank, and a digital flow meter and flow rate meter are displayed on the device control panel. When the flow exceeds the set value, it serves as a signal to start the pump. A pressure switch is also installed on the device's control panel, digitally displaying real-time pressure (the natural static pressure of the water tank and the outlet pressure of the pressure-stabilizing pump). When the high-level water tank and the static pressure-stabilizing pump pressure cannot support the large water flow during a fire, the pressure drops suddenly. When it drops to the set pressure, it serves as a reliable signal to directly start the fire pump.
According to the standard 1.0.4 of GB50974-2014, "Technical Specifications for Fire Water Supply and Fire Hydrant Systems", a flow switch or pressure switch should be installed on the outlet pipe of the high-level fire water tank to directly start the fire pump. According to the new standard GB509742014.11.0.19, the reliability of pump starting is often affected by the loss of weak electrical signals. Therefore, the necessity of starting the fire pump via the fire hydrant box button is low, and the investment in fire hydrant button pump starting is relatively large. Thus, the fire hydrant button should not be used as a direct pump starting signal, but only as an alarm signal. A flow switch is installed on the outlet pipe of the high-level water tank, and a digital flow meter and flow rate meter are displayed on the device control panel. When the flow exceeds the set value, it serves as a pump starting signal. A pressure switch is also installed on the device control panel, digitally displaying real-time pressure (the natural static pressure of the water tank and the outlet pressure of the pressure-stabilizing pump). When the high-level water tank and the static pressure-stabilizing pump pressure cannot support the large water flow during a fire, the pressure drops suddenly. When it drops to the set pressure, it serves as a reliable signal for directly starting the fire pump.
Hongan Fire-Fighting Equipment Co., Ltd. specializes in the research and development and manufacturing of various fire-fighting equipment. Products cover pre-action systems, wet alarm valve assemblies, dry alarm valve assemblies, deluge valve assemblies, water flow indicators, pressure switches, alarm valves, sprinklers, fire hydrants, foam fire extinguishing systems, fire extinguisher products and accessories, fire valves, fire hoses and related control components, etc., hundreds of models. All products are designed and manufactured strictly in accordance with national standards, and have passed the inspection of the National Fire Product Testing Center, and meet the requirements of voluntary certification of fire products.
The company continues to break through in product innovation, using advanced CAD design software and automated processing equipment to ensure the precision and performance stability of each product. Products are widely used in industrial plants, high-rise buildings, commercial complexes, underground garages, data centers, airports, schools and other key fire prevention places. Hong'an not only provides single-product sales, but also can customize complete fire protection system solutions according to customer needs, and has the ability of project-based supporting and technical services.
To ensure product quality, the company has established a complete quality management system. Raw material procurement is strictly screened, production processes are strictly controlled, and finished products must pass multiple performance tests before leaving the factory. Over the years, the company has established a stable sales network throughout the country and exported to international markets such as Southeast Asia, the Middle East, and South America with high-quality products, reasonable prices, and fast response services, and has won widespread recognition and trust from customers at home and abroad.
In the future, Hongan Fire-Fighting will continue to adhere to the mission of "guarding life safety", continuously promote technological innovation and product upgrades, and provide global users with more reliable and intelligent fire protection products and services.
Product Keywords:
Pressure switch